Why Is My Furnace Blowing Cold Air? 8 Causes and Fixes

Your furnace is running, but cold air is coming out of the vents. Here's how to diagnose the problem and decide whether it's a quick fix or a call to a professional.

Published: February 9, 2026
Read Time: 12 minutes
Category: Tips & Guides

It's mid-February in New Jersey, wind chills are plunging well below zero, and your furnace just started blowing cold air. Few home emergencies feel as urgent—especially when temperatures outside make a broken heater more than an inconvenience.

The good news: a furnace blowing cold air doesn't always mean a catastrophic failure. In fact, the two most common causes—a thermostat setting and a dirty filter—are things you can fix yourself in under five minutes. The bad news: some causes do require professional repair, and ignoring them can lead to bigger (and more expensive) problems.

Before you start troubleshooting, ask yourself one question: is the air truly cold, or is it room-temperature air that just feels cold against your skin? Hold your hand directly over a vent. If the air is the same temperature as the room (not heated, but not frigid), the furnace is likely cycling the fan without firing the burners. If it's genuinely ice-cold, you may have a ductwork issue pulling in unconditioned air. That distinction matters for narrowing down the cause.

Let's walk through the 8 most common reasons your furnace is blowing cold air—from the easiest fixes to the ones that need a technician.

Quick Diagnosis: Start Here

1.

Check your thermostat

Is the fan set to ON instead of AUTO?

2.

Check your air filter

Is it clogged or hasn't been changed in months?

3.

Check other gas appliances

Is your stove or water heater working? Could be a gas supply issue.

4.

Listen to the furnace

Clicking, banging, or repeated start-stop cycles?

If steps 1 and 2 don't solve it, keep reading for the full list of causes and fixes below.

8 Common Causes Your Furnace Is Blowing Cold Air

1

Thermostat Set to "ON" Instead of "AUTO"

Most common cause — 2-minute fix

This is the #1 reason furnaces blow cold air, and it catches homeowners off guard every winter. When your thermostat fan is set to "ON," the blower runs continuously—even between heating cycles when the burners aren't firing. That means you get blasts of unheated air between the warm cycles.

The Fix: Switch your thermostat fan from "ON" to "AUTO." In AUTO mode, the fan only runs when the burners are actively heating air. You should feel warm air within a few minutes.

Why it happens: Someone may have switched it during summer (continuous fan helps with cooling circulation) and forgot to switch it back. Some smart thermostats also have a "circulate" mode that runs the fan periodically—check your smart thermostat settings if you have one.

2

Dirty or Clogged Air Filter

Second most common — under $15 fix

A severely clogged filter restricts airflow through the furnace. With less air moving across the heat exchanger, the furnace overheats. When the internal temperature gets too high, the high-limit switch shuts off the burners as a safety measure—but the blower fan keeps running, pushing cold air through your vents.

During NJ's coldest weeks, your furnace runs harder and longer, pulling more debris through the filter. A filter that was fine in December can be completely clogged by mid-February.

The Fix: Turn off the furnace, pull out the filter, and hold it up to light. If you can't see through it, replace it. Restart the furnace and wait 15-20 minutes for the system to reset and begin heating normally.

Prevention: Check your filter monthly during winter. Need help choosing the right one? Read our complete air filter guide.

3

Pilot Light or Igniter Failure (Gas Furnaces)

Common in older systems — may need a pro

If the pilot light goes out or the electronic igniter fails, your gas furnace can't light the burners. The blower motor may still run (it's electric), so air moves through the vents—but it's never heated.

Older furnaces with standing pilot lights can have the pilot blown out by a strong draft. Newer furnaces use hot surface igniters or electronic spark ignition, which can crack or wear out over time.

The Fix: If you have a standing pilot light, you can try relighting it following the instructions on the furnace panel. For electronic ignition systems, this is typically a professional repair. Igniter replacement costs $150-$400.

Deep dive: Gas furnace won't ignite? Complete troubleshooting guide

4

Gas Supply Issues

Check other gas appliances first

No gas means no heat—but the blower still runs. This can happen if the gas valve to the furnace was accidentally turned off, there's a utility outage, or there's a problem with the gas line.

Quick Check: Try turning on your gas stove or another gas appliance. If nothing works, the issue is your gas supply, not the furnace. Check that the gas valve near the furnace is in the "on" position (handle parallel to the pipe). If you suspect a utility outage, contact your gas company.

If you smell gas: Leave the house immediately. Do not flip any switches. Call 911 from outside.

5

Overheated Furnace (Limit Switch Tripped)

Safety mechanism — needs attention

The high-limit switch is a safety device that shuts off the burners if the furnace gets too hot internally. The blower continues running to cool down the heat exchanger, which sends cold air through your vents. This is closely related to the dirty filter problem (Cause #2), but it can also happen from blocked supply vents, a failing blower motor, or a malfunctioning limit switch itself.

The Fix: Turn off the furnace at the thermostat. Wait 30 minutes for it to cool completely. Replace the air filter if it's dirty. Make sure all supply and return vents throughout the house are open and unblocked. Restart. If the limit switch trips again, call a technician—repeated overheating can crack the heat exchanger, which is a serious and expensive repair.

6

Malfunctioning Flame Sensor

$80–$250 professional repair

The flame sensor is a small metal rod that detects whether the gas burners are actually lit. If it's dirty or failing, it can't confirm a flame is present—so the furnace shuts off the gas as a safety precaution. You may notice the furnace igniting briefly (you hear it light), then shutting off after a few seconds, followed by cold air from the blower.

The Fix: A technician can often clean the flame sensor with fine sandpaper or steel wool—a quick, affordable repair ($80–$150). If the sensor is cracked or worn, replacement runs $150–$250 including labor.

Related: Complete gas furnace troubleshooting guide

7

Ductwork Leaks or Disconnection

Hidden problem — professional inspection recommended

Your furnace may be producing heat just fine—but if the ductwork has leaks, gaps, or a disconnected section, that heated air is escaping into your attic, crawlspace, or walls before it reaches your rooms. Meanwhile, unconditioned air gets pulled into the ducts, making the air from your vents feel cold.

Telltale signs: Some rooms are warm while others stay cold. You feel warm air near the furnace but cold air at distant vents. Your energy bills are unusually high despite a working furnace.

The Fix: Visually inspect accessible ductwork in your basement or attic for obvious gaps, disconnected joints, or damaged insulation. For a thorough assessment, schedule a professional duct inspection. The average NJ home loses 20–30% of heated air through duct leaks.

8

Condensate Drain Clog (High-Efficiency Furnaces)

Applies to 90%+ AFUE furnaces

High-efficiency condensing furnaces (90% AFUE and above) produce condensation as a byproduct of their extra heat extraction. This water drains through a condensate line. If that line clogs—from algae, sediment, or ice in extreme cold—a safety switch shuts down the furnace to prevent water damage.

The Fix: Check the condensate drain pan and line for standing water or visible blockage. You can try flushing the line with a mixture of warm water and vinegar. If the exterior drain is frozen (common during NJ cold snaps), carefully thaw it with warm water. If the problem recurs, call a technician.

Not sure about your furnace's efficiency rating? Read our AFUE efficiency guide to find out.

Gas vs. Electric vs. Oil: Which Causes Apply to Your Furnace?

Not all 8 causes apply to every furnace type. Here's a quick reference:

CauseGasElectricOil
Thermostat set to ONYesYesYes
Dirty air filterYesYesYes
Pilot light / igniter failureYesNoYes
Gas supply issuesYesNoNo*
Overheated / limit switchYesYesYes
Flame sensor malfunctionYesNoNo**
Ductwork leaksYesYesYes
Condensate drain clogYes***NoNo

*Oil furnaces can run out of fuel—check your tank level. **Oil furnaces use a cad cell sensor instead. ***Only high-efficiency (90%+ AFUE) gas furnaces.

Have an electric furnace? Read our dedicated guide: Electric furnace blowing cold air — causes and fixes. For gas-specific troubleshooting, see our gas furnace troubleshooting guide.

When to DIY vs. When to Call a Professional

Safe to DIY

  • • Switching thermostat from ON to AUTO
  • • Replacing a dirty air filter
  • • Relighting a standing pilot light
  • • Clearing blocked vents and registers
  • • Checking your gas valve position
  • • Flushing a condensate drain line

Call a Professional

  • • Electronic igniter or flame sensor issues
  • • Repeated limit switch tripping
  • • Gas smell near the furnace
  • • Furnace making banging or scraping sounds
  • • Electrical problems or tripped breakers
  • • Any repair involving gas lines or wiring

Safety Warning: Never Ignore a Gas Smell

If you smell rotten eggs or sulfur near your furnace, do not attempt any repairs. Leave the house immediately. Do not flip light switches, use your phone inside, or start your car in the garage. Call 911 from outside. Gas leaks are rare but extremely dangerous. Learn more in our furnace safety and carbon monoxide guide.

How to Prevent Your Furnace from Blowing Cold Air

Most furnace cold-air problems are preventable with basic maintenance. Here's what to do:

Change your filter monthly during winter

This single habit prevents the two most common causes of furnace cold-air problems (overheating and limit switch trips). Set a phone reminder for the first of every month. Our filter guide helps you choose the right filter for your system.

Schedule annual professional maintenance

A fall tune-up catches igniter wear, flame sensor buildup, and other issues before they leave you without heat. Professional maintenance can prevent up to 95% of emergency breakdowns. Know the signs your furnace needs a tune-up.

Keep all vents open and unblocked

Closing vents in unused rooms seems logical, but it actually increases pressure in the ducts and can cause the furnace to overheat. Keep all supply and return vents clear of furniture, rugs, and curtains.

Install carbon monoxide detectors

A furnace that overheats repeatedly or has a cracked heat exchanger can produce carbon monoxide. Install detectors on every floor and near bedrooms. Test them monthly. Read our carbon monoxide safety guide.

Don't ignore early warning signs

Strange noises, uneven heating, rising energy bills, and frequent cycling are all signs something is developing. Addressing these early saves you from a cold-air emergency later. Tips for lowering your winter heating bills.

Frequently Asked Questions

Why is my furnace blowing cold air all of a sudden?

The most common cause is your thermostat fan set to "ON" instead of "AUTO," which blows unheated air between heating cycles. Other causes include a dirty air filter triggering the safety shutoff, pilot light or igniter failure, or a tripped limit switch from overheating. Check the thermostat and filter first — these fix the problem about 60% of the time.

Is it dangerous if my furnace is blowing cold air?

In most cases, a furnace blowing cold air is not immediately dangerous — it usually means a component has failed or a safety switch has activated. However, if you smell gas, see soot around the furnace, or your carbon monoxide detector goes off, leave the house immediately and call 911. These could indicate a cracked heat exchanger or gas leak.

Why does my furnace blow hot air then cold air?

This cycling pattern typically indicates the furnace is overheating and the limit switch is shutting off the burners while the blower keeps running. Common causes are a clogged filter restricting airflow, blocked vents, or a failing blower motor. Replace your filter first. If the problem continues, call a technician — repeated overheating can crack the heat exchanger.

How much does it cost to fix a furnace blowing cold air?

Costs depend on the cause. A thermostat adjustment or filter replacement is under $30 DIY. Professional repairs range from $80-$250 for a flame sensor cleaning, $150-$400 for an igniter replacement, and $200-$600 for a gas valve replacement. Call Dimatic Control at (908) 249-9701 for transparent pricing.

Can a dirty filter really cause my furnace to blow cold air?

Yes. A severely clogged filter restricts airflow, causing the furnace to overheat. When the internal temperature gets too high, the limit switch shuts off the burners as a safety measure, but the blower fan keeps running — pushing cold air through your vents. During cold snaps like the current one in NJ, check your filter monthly and replace if dirty.

My furnace is running but the house isn't getting warm. What's wrong?

If the furnace is producing some heat but can't reach your set temperature, possible causes include duct leaks losing heated air, an undersized system struggling in extreme cold, a failing blower motor not pushing enough air, or significant air leaks in your home. During extreme cold with wind chills below zero, even properly working furnaces may run continuously without fully reaching the set temperature.

Should I keep running my furnace if it's blowing cold air?

If it's just a thermostat or filter issue, fix it and keep running. But if the furnace is repeatedly cycling on and off, making unusual noises, or you smell gas or burning, turn it off at the thermostat and call a professional. Running a malfunctioning furnace can cause further damage or create safety hazards. Keep your home above 55°F to prevent pipe freezing while you wait for repair.

Need Emergency Furnace Repair in Union County?

If your furnace is blowing cold air and the quick fixes above didn't solve it, we're here to help. Dimatic Control provides 24/7 emergency heating repair across Union County and Central New Jersey. Our technicians diagnose the problem fast, explain your options clearly, and get your heat back on.